Evaporadores Murales Industriales Verticales Ventilacion Frontal MC

Industrial wall type coolers

The industrial wall type coolers of the MC series have their application in cooling chambers and where a fast cooling process is required.

Capacity
  • 12,4kW – 100 kW
Catalogue

icon_clip Download: Español Français – English

open_new_window View On-line: Español Français – English

CONSTRUCTIVE CHARACTERISTICS

More information on some of the industrial wall type coolers  MC constructive characteristics is given bellow. Click each button to display the required details:

  • Built with high-quality raw materials: 5/8” copper tubes (0,43 mm thickness) expansion-jointed in aluminium fins with 8 o 10 mm thickness.
  • Internal careful cleaning of tubes.
  • Pressure checked: supplied with a dry nitrogen charge.
  • Outlet connection and liquid distributor, with the circuits and lengths appropriate for each application.
  • Can be supplied:
    -Equipped for GLYCOL WATER or similar.
    -12 mm fin spacing.

  • Structurally solid casing, in aluminium with white removable protection plastic, to prevend scratches during the transport and the setting up.
  • Laterals easy to dismantle to manipulate the expansion valve and the electrical connections.
  • Stainless steel bolts and supports.
  • External and internal tray, to avoid external condensation, in aluminium, with hinges, for an easy and convenient intervention.
  • STAINLESS STEEL, for a wider application, even in the strictest sectors of the food chain.

Air coolers equipped with Ziehl-abbeg or EBM fans, with external rotor and thermal protection:

  • The fans have safety grilles, in painted steel, according to the current safety regulations (CE).
  • The engines are wired to an own ground terminal.
  • The arrow air is indicated according CECOMAF regulation, on the distance at which the velocity is 0’25 m/s with the air coolers laid on the ground, without obstacles in his the way of the air.
  • The fans and resistances are wired in a respectively boxes, with a protection degree IP-54.
  • Can be supplied:
    -With MOUTHPIECE for an improved air address or AIR GUIDING GRID obtaining an uniform distribution of temperature in the chamber.
    -different ELECTRICAL specifications to those mentioned.
    -HOOP RESISTANCES for fans: in cooling or freezing chambers with extreme humidity conditions.

In the electric defrost, the principal resistance characteristics are:

  • Reinforced stainless steel materials, with vulcanized terminals on the tube: high protection against humidity and ice.
  • Strategically distributed, depending on the air cooler heat requirement.
  • Featured with special fixation on the end, to prevend movements by dilation.